NavArch Handbook
Chapter 1 / Section 1.6
Between two tabulated points , :
Adequate for hydrostatic tables at 0.1 m draught steps, KN tables at 10° steps within the linear range, and material property tables. Error is proportional to the second derivative of the underlying curve times the square of the interval.
Through three points :
Use for curved tables (KM vs draught near its minimum, GZ near its maximum, ) and for locating the maximum of a tabulated curve: the vertex of the parabola through three equally spaced points (spacing ) lies at
This is how the angle of maximum GZ is found from 10° ordinates (Tools page, IS Code check).
Piecewise cubics with continuous first and second derivatives through all points; the standard method in hydrostatics software for curves of KN, areas and Bonjean curves. Do not hand-compute; be aware that splines can oscillate near sharp changes (deck-edge immersion, knuckles) — check against the tabulated values.
Never extrapolate hydrostatic or KN tables beyond the tabulated range; the hull form changes (deck immersion, bilge emergence) make the curves non-polynomial.
For points :
Through the origin (physically required, e.g. inclining moment vs ): . Goodness of fit: (Section 1.8). Plot the residuals; a systematic pattern means the model (straight line) is wrong, not the data.
Resistance and power data are often fitted as (straight line in log–log); hydrostatic coefficients are sometimes given as polynomials in draught. Fit the lowest degree that follows the physics; a 5th-degree polynomial through 7 points reproduces the noise, not the curve.
KN tables are two-dimensional (displacement × heel angle): interpolate linearly in displacement at each tabulated angle first, then in angle if needed.
| Symbol | Description | Unit |
|---|---|---|
| Tabulated arguments bracketing x | as given | |
| Tabulated values | as given |
Result unit as given
Result unit as given
| Symbol | Description | Unit |
|---|---|---|
| Three consecutive ordinates with y_0 the largest tabulated | as given | |
| Spacing of the arguments | as given |
Result unit as given
Used to find the angle of maximum GZ from 10° ordinates.
| Symbol | Description | Unit |
|---|---|---|
| Slope | (unit y)/(unit x) | |
| Intercept | unit y |
Result unit -
Result unit -
Use when the physics requires y = 0 at x = 0 (inclining test: moment vs tan φ).
Result unit -
Worked example
Problem
The example vessel's hydrostatic table (Section 4.8) gives = 6.21 m at T = 4.50 m, 6.08 m at 5.00 m and 5.92 m at 6.00 m. Estimate at T = 5.50 m by (a) linear interpolation between 5.00 and 6.00 m and (b) quadratic interpolation through the three points, and compare with the tabulated 5.98 m.
Solution
(a) Linear: m.
(b) Lagrange with , , , :
; ; .
m.
The quadratic value (5.98 m) matches the table; the linear value is 2 cm high because KM is concave upward near its minimum. A 2 cm error in KM is a 2 cm error in GM — significant when GM is 0.70 m.
Worked example
Problem
GZ values (Example 5.4): 0.485 m at 30°, 0.536 m at 40°, 0.446 m at 50°. Find the angle and value of maximum GZ.
Solution
, , , .
These are the values the Tools page reports (38.6°, 0.537 m). The criterion is satisfied.