NavArch Handbook
Chapter 1 / Section 1.2
Multiply by ratios equal to one, writing every unit, and cancel:
Never convert in your head for anything that enters a design file; write the chain.
Every term of an equation must have the same dimensions. Use this as the first check of any formula copied from a rule or paper:
In stability, [t], moments [t·m] and [m] are consistent as long as all are mass-based; the righting moment in kN·m is . In structural analysis, loads must be forces: a 10 t crane load is . Mixing "t" as a force (tonne-force) with kN is the most common unit error in load tables received from suppliers — always ask whether a quoted "t" is mass or force.
Degrees for reporting heel, trim angle, rudder angle; radians inside every formula with trigonometric series, integration of GZ curves (m·rad), rotational stiffness and vibration (). A GZ-curve area of 0.090 m·rad is 5.16 m·deg.
Result unit -
Each ratio equals one; write the units and cancel.
| Symbol | Description | Unit |
|---|---|---|
| Depth below the still waterline | m |
Result unit kPa
Result unit kN·m
| Symbol | Description | Unit |
|---|---|---|
| Plate thickness | mm |
Result unit kg/m²
| Quantity | Rule of thumb |
|---|---|
| Sea pressure | ≈ 10 kPa per metre of depth |
| Steel plate | 7.85 kg/m² per mm of thickness; 10 mm plate = 78.5 kg/m² |
| Steel density | 7.85 t/m³ ≈ 7.7 × seawater |
| 1 t of seawater | 0.976 m³; 1 m³ of seawater = 1.025 t |
| 1 knot | ≈ 0.5 m/s ≈ 1.85 km/h |
| 1 bar | ≈ 10 m of water head ≈ 14.5 psi |
| 1 MPa | ≈ 10 bar ≈ 145 psi ≈ 0.102 kgf/mm² |
| 1 kN | ≈ 102 kgf (the weight of 102 kg) |
| Yield of mild steel | 235 MPa ≈ 24 kgf/mm² ≈ 34 ksi |
| 1 m·rad | 57.3 m·deg |
Worked example
Problem
A winch supplier states: 'Pull 25 t, brake holding load 40 t, mass 12.5 t, hydraulic pressure 280 bar, max line speed 60 m/min'. Convert to the handbook's units for a foundation calculation.
Solution
Pull and brake load are forces (tonne-force): ; . Mass 12.5 t is a mass: weight . Pressure . Speed . Design horizontal load on the foundation (brake case) plus dynamic factor per the governing standard; vertical load plus the vertical component of the line pull if the lead is inclined. Record in the calculation: 'Loads from supplier data sheet, tonnes interpreted as tonne-force, confirmed with supplier on <date>'.
Free download from nist.gov.
Rule formulas use mixed units (mm, m, kN/m²) by design; use exactly those stated.