NavArch Handbook
Chapter 2 / Section 2.12
The exact permissible stresses are in the governing document and change between editions. Indicative ranges are given in the table only to recognise an implausible result; take the design value from the standard in force and cite it in the calculation.
| Symbol | Description | Unit |
|---|---|---|
| Usage factor (permissible stress coefficient) for the load case | - | |
| Safety factor = 1/η | - | |
| Specified minimum yield stress (ReH) | MPa |
Result unit MPa
| Symbol | Description | Unit |
|---|---|---|
| Material factor | - |
Result unit MPa
e.g. hull girder 175/k: 175 (mild), 224 (AH32), 243 (AH36) MPa.
| Symbol | Description | Unit |
|---|---|---|
| Load factor for load i | - | |
| Characteristic load effect | as applicable | |
| Characteristic resistance | as applicable | |
| Material/resistance factor (DNV-OS-C101: 1.15; EC3 γ_M0 = 1.0) | - |
Result unit -
Result unit MPa
| Symbol | Description | Unit |
|---|---|---|
| Hoisting (dynamic) factor from the lifting standard (typically 1.1–1.3 harbour/offshore in-service; higher for subsea or offboard lifts) | - | |
| Safe working load (mass) | t |
Result unit kN
Take ψ, the load combinations and the allowables from DNV-ST-0378 (or the applicable standard) — never from this general form alone.
| Check | Standard | Indicative allowable | Comment |
|---|---|---|---|
| Hull girder bending, nominal | IACS UR S11 / DNV Pt.3 Ch.5 | 175/k MPa (≈ 0.75 σ_y for mild steel) | Shear 110/k MPa |
| Local bending of plating under lateral pressure | DNV Pt.3 Ch.6 | Rule coefficient ≈ 0.8–1.0 × σ_y/k in the thickness formula (includes membrane effect) | Formula-embedded |
| Stiffener bending (local + hull girder) | DNV Pt.3 Ch.6 | Rule coefficient; combined ≈ 0.8–0.9 σ_y/k | Formula-embedded |
| Primary members, coarse-mesh FE von Mises | DNV Pt.3 Ch.7 / CG-0127 | ≈ 0.9 σ_y/k (static + dynamic), lower for static alone | Element-size dependent |
| Fine-mesh FE (50 × 50 mm) peak von Mises | DNV CG-0127 | ≈ 1.5–1.7 × coarse allowable (local yielding accepted) | Mesh-size specific |
| Equipment foundations, operating | DNV-ST-0378 Sec. 4 (lifting appliances) | σ_e ≤ σ_y/γ with γ ≈ 1.5 (operating, in-service) | Confirm load case table |
| Equipment foundations, survival/stowed/accidental | DNV-ST-0378 | γ ≈ 1.1–1.33 (rarer cases) | Confirm |
| Steel members, Eurocode | EN 1993-1-1 | Factored loads vs f_y/γ_M0 (γ_M0 = 1.0) | LRFD format |
| Offshore steel, DNV LRFD | DNV-OS-C101 | γ_f 1.3 (permanent/variable, ULS-a) × S ≤ R/1.15 | LRFD format |
| Bolts | EN 1993-1-8 | F_v,Rd = 0.6 f_ub A_s/1.25 | Section 2.2 |
| Fillet welds | EN 1993-1-8 / class rules | f_u/(√3 β_w γ_M2); class: throat = factor × plate thickness | Section 8.3 |
Worked example
Problem
A deck crane on the example vessel: SWL 10 t at 12.0 m outreach; crane self-weight 15 t with CoG 3.0 m from the slew axis; hoisting (dynamic) factor ψ = 1.3 on the hook load (assumed design basis — confirm with DNV-ST-0378 for the actual crane class); ship heel 5° producing a horizontal component of the vertical loads at the pedestal top, 3.0 m above the deck; slewing torque 150 kN·m. Pedestal: tube Ø 1200 × 20 mm, mild steel σ_y = 235 MPa. Check the pedestal shell at the deck connection with an indicative usage factor η = 0.85 (operating). Then list the further checks required.
Solution
Loads. Vertical: kN.
Overturning moment at the pedestal top: kN·m.
Horizontal from 5° heel: kN; additional moment at the deck: kN·m. Total kN·m. Torque kN·m.
Section (mean radius 590 mm, t = 20 mm): mm²; mm⁴; mm³; mm².
Stresses at the extreme compression fibre. MPa; MPa; MPa (compression). Torsional shear MPa; transverse shear at the extreme fibre ≈ 0 (maximum MPa at the neutral axis).
Allowable and unity check. MPa (indicative). ✓.
Further checks required before this foundation is accepted:
For cranes and their pedestals/foundations under DNV certification; confirm edition in force.
Confirm section numbering in the edition in force.
Offshore units; given here for comparison of formats.