Chapter 2 / Section 2.12
Allowable stresses and safety factors in rule-based design
Two formats
- Working (allowable) stress design: the computed stress under the characteristic (unfactored) load must not exceed an allowable stress (or ). Classification society hull rules, DNV-ST-0378 (lifting appliances) and most equipment standards use this format. The usage factor (or permissible stress coefficient) depends on the load case and on what is checked.
- Partial-factor (LRFD) design: factored loads against factored resistance . Eurocodes (EN 1993: , , ) and DNV offshore standards (DNV-OS-C101: for steel yield, load factors 1.3/0.7 ULS-a and 1.0/1.3 ULS-b) use this format. Never mix the two formats in one check.
What the allowable depends on
- Load case: operating (frequent) vs survival/extreme (rare) vs accidental — the rarer the load, the higher the permitted fraction of yield (typically ≈ 0.6–0.7 operating, 0.8–0.9 extreme, up to 1.0 accidental/ALS). Lifting: in-service vs stowed vs overload test.
- Stress type: hull girder nominal (175/k MPa in IACS UR S11), local bending of stiffeners and plates (rule coefficients), shear ( or an explicit value), von Mises in FE (coarse mesh vs fine mesh — different allowables because the fine mesh captures peaks), weld throat.
- Material factor (DNV, IACS): 1.0 for 235 MPa, 0.78 for 315, 0.72 for 355, 0.68 for 390 — the allowable is scaled by , i.e. not proportionally to yield (Section 3.2).
- Consequence and redundancy: primary members vs secondary; single load path (pedestal, lifting lug) vs redundant.
- Dynamic amplification: already in the load (DAF, hoisting factor ψ, motion accelerations) — not in the allowable; do not apply both a dynamic factor and a reduced allowable unless the standard says so.
Where to find the numbers
The exact permissible stresses are in the governing document and change between editions. Indicative ranges are given in the table only to recognise an implausible result; take the design value from the standard in force and cite it in the calculation.
Structure of a rule-based check (report format)
- Load case definition (standard, section, load factors / dynamic factors).
- Loads (magnitude, point of application, direction) with source.
- Section properties (net or gross — state) and material (, ).
- Stresses (axial, bending, shear, torsion, combined).
- Allowable from the standard (document, section, load case).
- Unity check ; buckling and fatigue checks where applicable.
- Conclusion with the governing element and the margin.
Common errors
- Comparing a fine-mesh FE peak stress with a nominal-stress allowable (or the reverse).
- Using gross scantlings where the rule requires net (or vice versa).
- Applying the operating-case allowable to a survival load, or doubling dynamic factors.
- Scaling the allowable linearly with yield for high-strength steel instead of using .
- Omitting the buckling check for members in compression that pass the yield check.
- Treating the crane maker's "SWL" as the design load without the hoisting/dynamic factor of the structural standard.
Formulas
| Symbol | Description | Unit |
|---|---|---|
| Usage factor (permissible stress coefficient) for the load case | - | |
| Safety factor = 1/η | - | |
| Specified minimum yield stress (ReH) | MPa |
Result unit MPa
| Symbol | Description | Unit |
|---|---|---|
| Material factor | - |
Result unit MPa
e.g. hull girder 175/k: 175 (mild), 224 (AH32), 243 (AH36) MPa.
| Symbol | Description | Unit |
|---|---|---|
| Load factor for load i | - | |
| Characteristic load effect | as applicable | |
| Characteristic resistance | as applicable | |
| Material/resistance factor (DNV-OS-C101: 1.15; EC3 γ_M0 = 1.0) | - |
Result unit -
Result unit MPa
| Symbol | Description | Unit |
|---|---|---|
| Hoisting (dynamic) factor from the lifting standard (typically 1.1–1.3 harbour/offshore in-service; higher for subsea or offboard lifts) | - | |
| Safe working load (mass) | t |
Result unit kN
Take ψ, the load combinations and the allowables from DNV-ST-0378 (or the applicable standard) — never from this general form alone.
Tables
Indicative usage factors / allowable stresses in common standards (orientation only — take design values from the standard in force)
| Check | Standard | Indicative allowable | Comment |
|---|---|---|---|
| Hull girder bending, nominal | IACS UR S11 / DNV Pt.3 Ch.5 | 175/k MPa (≈ 0.75 σ_y for mild steel) | Shear 110/k MPa |
| Local bending of plating under lateral pressure | DNV Pt.3 Ch.6 | Rule coefficient ≈ 0.8–1.0 × σ_y/k in the thickness formula (includes membrane effect) | Formula-embedded |
| Stiffener bending (local + hull girder) | DNV Pt.3 Ch.6 | Rule coefficient; combined ≈ 0.8–0.9 σ_y/k | Formula-embedded |
| Primary members, coarse-mesh FE von Mises | DNV Pt.3 Ch.7 / CG-0127 | ≈ 0.9 σ_y/k (static + dynamic), lower for static alone | Element-size dependent |
| Fine-mesh FE (50 × 50 mm) peak von Mises | DNV CG-0127 | ≈ 1.5–1.7 × coarse allowable (local yielding accepted) | Mesh-size specific |
| Equipment foundations, operating | DNV-ST-0378 Sec. 4 (lifting appliances) | σ_e ≤ σ_y/γ with γ ≈ 1.5 (operating, in-service) | Confirm load case table |
| Equipment foundations, survival/stowed/accidental | DNV-ST-0378 | γ ≈ 1.1–1.33 (rarer cases) | Confirm |
| Steel members, Eurocode | EN 1993-1-1 | Factored loads vs f_y/γ_M0 (γ_M0 = 1.0) | LRFD format |
| Offshore steel, DNV LRFD | DNV-OS-C101 | γ_f 1.3 (permanent/variable, ULS-a) × S ≤ R/1.15 | LRFD format |
| Bolts | EN 1993-1-8 | F_v,Rd = 0.6 f_ub A_s/1.25 | Section 2.2 |
| Fillet welds | EN 1993-1-8 / class rules | f_u/(√3 β_w γ_M2); class: throat = factor × plate thickness | Section 8.3 |
Examples
Crane pedestal foundation check (working stress format)
Worked example
Problem
A deck crane on the example vessel: SWL 10 t at 12.0 m outreach; crane self-weight 15 t with CoG 3.0 m from the slew axis; hoisting (dynamic) factor ψ = 1.3 on the hook load (assumed design basis — confirm with DNV-ST-0378 for the actual crane class); ship heel 5° producing a horizontal component of the vertical loads at the pedestal top, 3.0 m above the deck; slewing torque 150 kN·m. Pedestal: tube Ø 1200 × 20 mm, mild steel σ_y = 235 MPa. Check the pedestal shell at the deck connection with an indicative usage factor η = 0.85 (operating). Then list the further checks required.
References
For cranes and their pedestals/foundations under DNV certification; confirm edition in force.
Confirm section numbering in the edition in force.
Offshore units; given here for comparison of formats.
Version 2 · last updated 19 Nov 2026 · Editor