NavArch Handbook
Chapter 2 / Section 2.4
For a beam in pure bending about a principal axis, plane sections remain plane and the normal stress varies linearly from the neutral axis:
is the second moment of area about the neutral axis (which passes through the centroid for pure bending of a homogeneous section) and (also or ) the section modulus. For an unsymmetrical section there are two section moduli — to the top fibre and to the bottom fibre — and the smaller governs the stress check; in a stiffener-plate combination the flange modulus is the smaller (Section 2.5).
Classification rules give the required section modulus in cm³ and the inertia in cm⁴, with spans in m, spacing in mm and pressures in kN/m²: a typical form is where the constant absorbs the unit conversions and the end-fixity coefficient. Convert consistently: , .
with the first moment of the area beyond and the width at . For I- and T-sections the web carries practically all the shear; the engineering approximation (with ) is used in class rules as the shear area requirement. For a rectangle ; for a solid circle ; for a thin-walled tube .
Transform the stiffer material by the modular ratio (multiply widths by ); compute of the transformed section; stresses in material 1 are multiplied back by . Used for aluminium superstructures on steel hulls (with a flexible joint the superstructure is often excluded from the hull girder), for FRP sandwich (Section 3.6) and for steel inserts in aluminium craft.
The flexure formula assumes span/depth > ~5 and small curvature. Brackets, deep web frames with large openings and slew-ring supports require shell/FE analysis (Section 7.11).
Rules use the elastic . The plastic modulus (fully yielded section) is 1.1–1.5 times larger for stiffened plates; it is relevant to ultimate strength and accidental loads (collision, grounding), not to the normal rule check.
| Symbol | Description | Unit |
|---|---|---|
| Normal bending stress at distance z from the neutral axis | MPa | |
| Bending moment | N·mm | |
| Distance from the neutral axis (positive away from the compression side as per sign convention) | mm | |
| Second moment of area about the neutral axis | mm⁴ |
Result unit MPa
With M in kN·m, I in cm⁴ and z in cm: σ [MPa] = 100 M z / I.
| Symbol | Description | Unit |
|---|---|---|
| Elastic section modulus to the extreme fibre considered | mm³ (rules: cm³) | |
| Distance from the neutral axis to the extreme fibre | mm |
Result unit MPa
σ [MPa] = 1000 M [kN·m] / W [cm³].
Result unit mm³
| Symbol | Description | Unit |
|---|---|---|
| First moment about the neutral axis of the area beyond z | mm³ | |
| Width of the section at z | mm |
Result unit MPa
| Symbol | Description | Unit |
|---|---|---|
| Web height | mm | |
| Web thickness | mm |
Result unit MPa
Rules state a required shear area A_w in cm².
Result unit MPa
| Symbol | Description | Unit |
|---|---|---|
| Modular ratio | - | |
| Second moment of the material-1 area (untransformed) about the common neutral axis | mm⁴ |
Result unit MPa
Steel/aluminium: n = 206/70 = 2.94.
| Profile | Area [cm²] | [cm⁴] | to flange tip [cm³] | Mass [kg/m] |
|---|---|---|---|---|
| Flat bar 100 × 10 | 10.0 | 83.3 | 16.7 | 7.85 |
| Flat bar 150 × 12 | 18.0 | 337.5 | 45.0 | 14.1 |
| Flat bar 200 × 15 | 30.0 | 1000 | 100 | 23.6 |
| Bulb flat HP 120 × 7 | 10.4 | 142 | 21.8 | 8.2 |
| Bulb flat HP 160 × 8 | 15.7 | 372 | 41.8 | 12.3 |
| Bulb flat HP 200 × 10 | 24.4 | 915 | 82.5 | 19.2 |
| Bulb flat HP 240 × 11 | 32.6 | 1770 | 133 | 25.6 |
| Angle L 100 × 75 × 8 | 13.5 | 135 (about axis ∥ to 75 leg) | 19.5 | 10.6 |
| T 200 × 10 + 80 × 12 (built-up) | 29.6 | 1397 (about own NA, 134.4 mm from web foot) | — | 23.2 |
The stiffener's own properties are only intermediate values; the design property is the modulus of the stiffener WITH its attached plate (Section 2.5).
Worked example
Problem
Using the moments of Example 2.3 (fixed ends: 7.20 kN·m at the support; simply supported: 10.80 kN·m) and the section properties of the T-stiffener with attached plate from Example 2.5 ( cm⁴, cm³, cm³, web 200 × 10 mm), compute the bending stresses at the flange and at the plate and the web shear stress for V = 18.0 kN.
Solution
Fixed-ended (rule assumption), at the support:
Simply supported, at midspan: MPa; MPa.
Web shear: mm² = 20 cm²; MPa.
All values are far below the allowable for local bending in a deck (of the order of 0.6–0.8 σ_y ≈ 140–190 MPa for mild steel, see Section 2.12), as expected for a 25 kPa deck load on a 200 mm stiffener; the stiffener size on a PSV deck is usually governed by heavier point loads (containers, deck cargo lashings) or by the hull-girder contribution, not by the uniform pressure. The flange modulus (307 cm³) governs because it is the smaller — confirm this against the rule-required Z in Section 7.6.
Rule form Z = C s ℓ² p / σ in cm³; confirm section numbers in the edition in force.