NavArch Handbook
Chapter 2 / Section 2.10
A compression member or plate becomes unstable at a critical load that depends on stiffness (, ) and geometry (slenderness), not on yield strength — until the critical stress approaches yield, where the two interact. High-strength steel does not raise the elastic buckling stress.
= effective length factor (table). Valid while (slender columns, = 132 for mild steel).
For (stocky columns and most ship plating):
This parabola is used by DNV and many ship rules to connect the elastic buckling stress to yield. Eurocode 3 uses instead the Perry–Robertson-type buckling curves ( factors, curves a0–d) which include initial imperfections explicitly; for hot-finished tubes curve a applies.
Rules give the pillar's required area as a function of load, length and radius of gyration (DNV Pt.3 Ch.6 — pillars), essentially the Euler/Johnson approach with a usage factor. Load: the deck reaction at the pillar head (tributary deck area × pressure, plus loads from decks above transmitted by pillars in line). Effective length: between deck connections, (pinned) unless the end brackets justify less.
For a rectangular plate simply supported on four edges under uniaxial compression along :
for (minimum over the number of half-waves); for a single half-wave; for a long plate compressed in the short direction ( transverse to the load) (wide plate — relevant to transversely framed decks). Shear: (), . Combined loads: interaction formulas (DNV-RP-C201).
Plate slenderness: ; plates with are "stocky" (yield before buckling), typical of deck plating.
A plate does not collapse at : the edges near the stiffeners continue to carry load. The effective width (von Kármán: ; Faulkner: ) is used for the ultimate strength of stiffened panels and the hull girder (Section 7.3 and 7.8).
Failure modes: plate buckling between stiffeners; stiffener column (flexural) buckling with the plate as flange; tripping (lateral-torsional buckling of the stiffener) — prevented by tripping brackets and by limits on flange proportions; overall grillage buckling. DNV-RP-C201 and the PULS code (DNV) treat these; Section 7.8.
Cylindrical shells (pedestals, masts, pipes) in axial compression and bending buckle at (classical, perfect shell) but real shells reach only 20–60 % of this because of imperfection sensitivity; use DNV-RP-C202 or EN 1993-1-6.
| Symbol | Description | Unit |
|---|---|---|
| Euler critical load | N | |
| Effective length factor | - | |
| Unsupported length | mm | |
| Slenderness ratio | - | |
| Radius of gyration about the weaker axis | mm |
Result unit N, MPa
Result unit -
| Symbol | Description | Unit |
|---|---|---|
| Elastic (Euler or plate) critical stress | MPa |
Result unit MPa
Applies to columns and to plates (with σ_E = plate elastic buckling stress).
| Symbol | Description | Unit |
|---|---|---|
| Buckling coefficient (4.0 for long simply supported plate loaded along a) | - | |
| Plate width perpendicular to the compression (stiffener spacing) | mm | |
| Number of half-waves along a | - |
Result unit MPa
Result unit MPa
Result unit -
β ≈ 2.0 for 600/10 mild steel; σ_cr(elastic)/σ_y = 3.6/β² for k = 4.
Result unit -
| Symbol | Description | Unit |
|---|---|---|
| Shell radius | mm |
Result unit MPa
Perfect shell; real shells 20–60 % of this. Use DNV-RP-C202.
| Symbol | Description | Unit |
|---|---|---|
| Reduction factor from buckling curve a0–d as a function of λ̄ | - | |
| Partial factor (1.0 in EN 1993-1-1 recommended) | - |
Result unit N
| End conditions | Theoretical K | Recommended design K | Ship example |
|---|---|---|---|
| Pinned – pinned | 1.0 | 1.0 | Pillar between decks with simple end connections |
| Fixed – fixed | 0.5 | 0.65 | Pillar with full-depth brackets top and bottom (rarely credited) |
| Fixed – pinned | 0.7 | 0.8 | Pillar bracketed at one end |
| Fixed – free (cantilever) | 2.0 | 2.1 | Mast, davit post, pedestal without top restraint |
| Fixed – translating (sway, rotation fixed) | 1.0 | 1.2 | Portal frame leg |
| Pinned – translating | 2.0 | 2.0 | Unbraced frame |
| (load along a) | (min over m) | Half-waves m |
|---|---|---|
| 0.5 (wide plate, load across short side) | 6.25 | 1 |
| 0.7 | 4.53 | 1 |
| 1.0 | 4.00 | 1 |
| 1.414 | 4.50 → 4.00 transition | 1–2 |
| 2.0 | 4.00 | 2 |
| 3.0 | 4.00 | 3 |
| ≥ 1 (any), long plate | 4.00 | a/b |
Clamped long edges: k ≈ 6.97. Unloaded edges one simply supported one free (flange outstand): k ≈ 0.425.
| [MPa] | (J–O) [MPa] | |||
|---|---|---|---|---|
| 30 | 1.01 | 828 | 218 | 0.93 |
| 40 | 1.35 | 466 | 205 | 0.87 |
| 50 | 1.69 | 298 | 189 | 0.80 |
| 60 | 2.03 | 207 | 168 | 0.72 |
| 70 | 2.37 | 152 | 144 | 0.61 |
| 80 | 2.70 | 116 | 116 (elastic, σ_E < σ_y/2) | 0.50 |
| 100 | 3.38 | 74.5 | 74.5 | 0.32 |
Worked example
Problem
A tubular pillar Ø 219.1 × 8.0 mm (hot-finished CHS, S235) is 3.00 m long between decks with simple end connections (K = 1.0) and carries a design axial load of 450 kN. Determine the slenderness, the Euler and Johnson–Ostenfeld critical stresses, the critical load, and the usage factor; compare with the Eurocode 3 buckling resistance (curve a).
Solution
Section (Example 2.6): mm², mm⁴, mm.
Slenderness: (< λ_lim = 132 → inelastic range).
Euler stress: MPa (> σ_y/2 = 117.5).
Johnson–Ostenfeld: MPa; kN.
Applied stress: MPa. Usage factor . With a permissible usage factor of 0.70 (indicative for pillars under operating loads — take the exact value from DNV Pt.3 Ch.6 or the governing standard): ✓.
Eurocode 3 comparison: ; ; curve a → ; kN — within 1.5 % of the Johnson–Ostenfeld value. Yield alone would allow kN; buckling reduces the capacity by only 5 % for this stocky pillar. A 6.0 m pillar of the same tube would have λ = 80.4, σ_E = 315 MPa, σ_cr = 191 MPa — an 18 % reduction.
Worked example
Problem
Deck plating 10 mm, longitudinal stiffeners at 600 mm, frames at 2400 mm, mild steel. The hull girder sagging stress in the deck is 120 MPa (compression). Check the plate panel for buckling.
Solution
.
→ Johnson–Ostenfeld: MPa. Slenderness .
Usage: . Against a typical permissible usage factor of 0.8–0.9 for hull girder buckling of plating (sagging, deck) — take the exact factor from DNV Pt.3 Ch.8 / RP-C201 — the panel is acceptable with a modest margin. Note that AH36 plating of the same thickness would have the same σ_E = 207 MPa but σ_cr = 355(1 − 355/828) = 203 MPa: the higher yield helps only through the inelastic correction. Effective width after buckling (Faulkner): — used in the ultimate hull girder strength (Section 7.3).
Referenced by DNV Rules Pt.3 Ch.8; confirm edition.
Confirm section numbering in the edition in force.