Chapter 2 / Section 2.10
Column and plate buckling
Buckling as a stability problem
A compression member or plate becomes unstable at a critical load that depends on stiffness (, ) and geometry (slenderness), not on yield strength — until the critical stress approaches yield, where the two interact. High-strength steel does not raise the elastic buckling stress.
Euler column
= effective length factor (table). Valid while (slender columns, = 132 for mild steel).
Inelastic range — Johnson–Ostenfeld correction
For (stocky columns and most ship plating):
This parabola is used by DNV and many ship rules to connect the elastic buckling stress to yield. Eurocode 3 uses instead the Perry–Robertson-type buckling curves ( factors, curves a0–d) which include initial imperfections explicitly; for hot-finished tubes curve a applies.
Pillars in ships
Rules give the pillar's required area as a function of load, length and radius of gyration (DNV Pt.3 Ch.6 — pillars), essentially the Euler/Johnson approach with a usage factor. Load: the deck reaction at the pillar head (tributary deck area × pressure, plus loads from decks above transmitted by pillars in line). Effective length: between deck connections, (pinned) unless the end brackets justify less.
Plate buckling (elastic)
For a rectangular plate simply supported on four edges under uniaxial compression along :
for (minimum over the number of half-waves); for a single half-wave; for a long plate compressed in the short direction ( transverse to the load) (wide plate — relevant to transversely framed decks). Shear: (), . Combined loads: interaction formulas (DNV-RP-C201).
Plate slenderness: ; plates with are "stocky" (yield before buckling), typical of deck plating.
Post-buckling and effective width
A plate does not collapse at : the edges near the stiffeners continue to carry load. The effective width (von Kármán: ; Faulkner: ) is used for the ultimate strength of stiffened panels and the hull girder (Section 7.3 and 7.8).
Stiffened panels and tripping
Failure modes: plate buckling between stiffeners; stiffener column (flexural) buckling with the plate as flange; tripping (lateral-torsional buckling of the stiffener) — prevented by tripping brackets and by limits on flange proportions; overall grillage buckling. DNV-RP-C201 and the PULS code (DNV) treat these; Section 7.8.
Shells
Cylindrical shells (pedestals, masts, pipes) in axial compression and bending buckle at (classical, perfect shell) but real shells reach only 20–60 % of this because of imperfection sensitivity; use DNV-RP-C202 or EN 1993-1-6.
Formulas
| Symbol | Description | Unit |
|---|---|---|
| Euler critical load | N | |
| Effective length factor | - | |
| Unsupported length | mm | |
| Slenderness ratio | - | |
| Radius of gyration about the weaker axis | mm |
Result unit N, MPa
Result unit -
| Symbol | Description | Unit |
|---|---|---|
| Elastic (Euler or plate) critical stress | MPa |
Result unit MPa
Applies to columns and to plates (with σ_E = plate elastic buckling stress).
| Symbol | Description | Unit |
|---|---|---|
| Buckling coefficient (4.0 for long simply supported plate loaded along a) | - | |
| Plate width perpendicular to the compression (stiffener spacing) | mm | |
| Number of half-waves along a | - |
Result unit MPa
Result unit MPa
Result unit -
β ≈ 2.0 for 600/10 mild steel; σ_cr(elastic)/σ_y = 3.6/β² for k = 4.
Result unit -
| Symbol | Description | Unit |
|---|---|---|
| Shell radius | mm |
Result unit MPa
Perfect shell; real shells 20–60 % of this. Use DNV-RP-C202.
| Symbol | Description | Unit |
|---|---|---|
| Reduction factor from buckling curve a0–d as a function of λ̄ | - | |
| Partial factor (1.0 in EN 1993-1-1 recommended) | - |
Result unit N
Tables
Effective length factors K for columns
| End conditions | Theoretical K | Recommended design K | Ship example |
|---|---|---|---|
| Pinned – pinned | 1.0 | 1.0 | Pillar between decks with simple end connections |
| Fixed – fixed | 0.5 | 0.65 | Pillar with full-depth brackets top and bottom (rarely credited) |
| Fixed – pinned | 0.7 | 0.8 | Pillar bracketed at one end |
| Fixed – free (cantilever) | 2.0 | 2.1 | Mast, davit post, pedestal without top restraint |
| Fixed – translating (sway, rotation fixed) | 1.0 | 1.2 | Portal frame leg |
| Pinned – translating | 2.0 | 2.0 | Unbraced frame |
Plate buckling coefficient k for a simply supported plate under uniaxial compression
| (load along a) | (min over m) | Half-waves m |
|---|---|---|
| 0.5 (wide plate, load across short side) | 6.25 | 1 |
| 0.7 | 4.53 | 1 |
| 1.0 | 4.00 | 1 |
| 1.414 | 4.50 → 4.00 transition | 1–2 |
| 2.0 | 4.00 | 2 |
| 3.0 | 4.00 | 3 |
| ≥ 1 (any), long plate | 4.00 | a/b |
Clamped long edges: k ≈ 6.97. Unloaded edges one simply supported one free (flange outstand): k ≈ 0.425.
Elastic buckling and Johnson–Ostenfeld critical stress of mild-steel plating, k = 4, σ_y = 235 MPa
| [MPa] | (J–O) [MPa] | |||
|---|---|---|---|---|
| 30 | 1.01 | 828 | 218 | 0.93 |
| 40 | 1.35 | 466 | 205 | 0.87 |
| 50 | 1.69 | 298 | 189 | 0.80 |
| 60 | 2.03 | 207 | 168 | 0.72 |
| 70 | 2.37 | 152 | 144 | 0.61 |
| 80 | 2.70 | 116 | 116 (elastic, σ_E < σ_y/2) | 0.50 |
| 100 | 3.38 | 74.5 | 74.5 | 0.32 |
Examples
Buckling check of a deck pillar
Worked example
Problem
A tubular pillar Ø 219.1 × 8.0 mm (hot-finished CHS, S235) is 3.00 m long between decks with simple end connections (K = 1.0) and carries a design axial load of 450 kN. Determine the slenderness, the Euler and Johnson–Ostenfeld critical stresses, the critical load, and the usage factor; compare with the Eurocode 3 buckling resistance (curve a).
Elastic buckling of deck plating under hull girder compression
Worked example
Problem
Deck plating 10 mm, longitudinal stiffeners at 600 mm, frames at 2400 mm, mild steel. The hull girder sagging stress in the deck is 120 MPa (compression). Check the plate panel for buckling.
References
Referenced by DNV Rules Pt.3 Ch.8; confirm edition.
Confirm section numbering in the edition in force.
Version 2 · last updated 19 Nov 2026 · Editor