NavArch Handbook
Chapter 2 / Section 2.6
For small deflections of an elastic beam (Euler–Bernoulli):
Integrate twice with the boundary conditions (deflection and slope zero at a fixed end; deflection and moment zero at a simple support; shear and moment zero at a free end). Shear deformation adds — negligible for span/depth > 10, significant for short deep girders and sandwich panels (Section 3.6).
The maximum deflections of the common cases are in the table of Section 2.3. The most used:
For linear elastic structures, deflections from several loads add. Combine standard cases (UDL + point load; load + end moment) instead of integrating from scratch. Statically indeterminate beams: release a redundant support, compute the deflection there from the loads, and add the deflection from the unknown reaction; set the sum to zero (compatibility) and solve.
Write with step functions (zero for ) so that one expression covers the whole span; integrate as a polynomial. Efficient for beams with several point loads (e.g. a shaft with several bearings, a girder with pillars).
Castigliano: with ; unit-load method: . Useful for frames and curved members (davits, A-frames).
Deflection seldom governs ship primary structure (rules control stress and buckling) but it governs: machinery seatings and shaft alignment (bearing offsets of ~0.1 mm matter), crane pedestals and slew rings (manufacturer limits on out-of-flatness and tilt, often ≤ 1 mrad), hatch covers and large openings (sealing), accommodation decks (vibration and perceived stiffness), and sandwich/FRP panels. Typical limits used in practice: – for deck plating under local loads, – for girders carrying equipment, stricter per supplier for shaft lines and slew rings.
is the only material-and-geometry parameter in deflection. Replacing mild steel by high-strength steel does not reduce deflection (same ); replacing steel by aluminium triples it for the same section. Stiffness (e.g. for a central point load) is used in vibration estimates () — Section 9.10.
| Symbol | Description | Unit |
|---|---|---|
| Deflection (positive downward) | mm | |
| Flexural rigidity | N·mm² |
Result unit mm
| Symbol | Description | Unit |
|---|---|---|
| Uniformly distributed load | N/mm | |
| Span | mm |
Result unit mm
Result unit mm
| Symbol | Description | Unit |
|---|---|---|
| Point load at the tip | N | |
| Slope at the tip | rad |
Result unit mm
Result unit mm
| Symbol | Description | Unit |
|---|---|---|
| Moment from the actual loads | N·mm | |
| Moment from a unit load at the point and in the direction of the required deflection | mm |
Result unit mm
| Symbol | Description | Unit |
|---|---|---|
| Stiffness | N/m | |
| Effective mass | kg | |
| Natural frequency | Hz |
Result unit Hz
| Element | Limit (span L) | Governing concern | Source |
|---|---|---|---|
| Deck/bulkhead plating between stiffeners under local load | L/100 – L/150 | Appearance, coating cracking | Practice; not a rule limit |
| Secondary stiffeners | L/150 – L/200 | Serviceability | Practice |
| Deck girders carrying equipment | L/250 – L/400 | Equipment alignment | Practice; supplier |
| Crane pedestal top flange (slew ring) | Flatness ≤ 0.5–1.0 mm; tilt ≤ 1 mrad under load (typical) | Slew bearing life | Crane maker; DNV-ST-0378 refers to maker's limits |
| Engine seating / shaft line | Bearing offsets per alignment calculation (0.1 mm order) | Shaft alignment | Engine/shaft maker; class alignment calculation |
| Hatch covers | L/300 – L/500 (sealing) | Weathertightness | Hatch cover maker |
| Sandwich/FRP panels (small craft) | L/100 – L/200 | Core shear, appearance | ISO 12215-5 (stiffness criteria for panels) |
Worked example
Problem
The T-stiffener with plate of Example 2.5 ( cm⁴ mm⁴) spans 2.40 m under kN/m. Find the midspan deflection for fixed ends and for simple supports.
Solution
kN/m N/mm; mm; N·mm². mm⁴.
Fixed ends: mm .
Simply supported: mm .
Both are negligible against any serviceability limit; deck stiffeners under uniform pressure are stress- (and buckling-) governed, not deflection-governed.
Worked example
Problem
A davit arm is a cantilever tube Ø 219.1 × 8.0 mm (CHS), length 3.0 m, with a working load of 15 kN at the tip (including dynamic factor). Steel S235. Check bending stress against 0.8 σ_y and tip deflection against L/150.
Solution
Section: mm²; mm⁴; mm³.
Moment at the root: kN·m. MPa; allowable MPa → (pass, small margin).
Tip deflection: mm — exceeds mm.
Here deflection governs: a stiffer tube (Ø 244.5 × 8, mm⁴, mm = L/190) is required even though the stress check passes. For lifting appliances the governing standard (e.g. DNV-ST-0378 for offshore cranes, or the Administration's LSA requirements for lifeboat davits) sets the load factors and allowables; the figures here illustrate the method only.