NavArch Handbook
Chapter 2 / Section 2.5
A stiffener welded to plating bends together with a strip of the plate. The design section is therefore stiffener + attached plate flange; the stiffener alone has a much smaller modulus and would give a grossly conservative (wrong) stress. The neutral axis of the combined section lies close to the plate, so the flange of the stiffener is the highly stressed fibre and the plate fibre is lightly stressed.
For a bulb flat (HP) or angle, take , own and centroid height from the manufacturer's table and treat the profile as one "part" in the table above. Angles and bulb flats are unsymmetrical; the rule modulus is nevertheless taken about the axis parallel to the plate because the plate prevents lateral deflection; lateral-torsional (tripping) behaviour is checked separately (Section 2.10).
Rule section moduli are compared on the net section (gross scantlings minus the corrosion addition on every plate element) in current DNV rules; older rules compared gross scantlings against a requirement that included the allowance. Always state which basis is used (Section 3.8).
For a T- or angle-stiffener with attached plate, the combined modulus to the flange is roughly 1.6–2.5 times the modulus of the profile alone, and the neutral axis lies at 15–30 % of the stiffener height above the plate. Use only for sanity checks.
| Symbol | Description | Unit |
|---|---|---|
| Area of element i (plate flange, web, face plate) | mm² | |
| Height of the centroid of element i above the reference line | mm |
Result unit mm
| Symbol | Description | Unit |
|---|---|---|
| Width and height (in the bending direction) of rectangular element i | mm |
Result unit mm⁴
Divide by 10⁴ for cm⁴.
| Symbol | Description | Unit |
|---|---|---|
| Total depth from the reference line to the top of the face plate | mm |
Result unit mm³
The smaller (flange) value governs the stress check. Divide by 10³ for cm³.
| Symbol | Description | Unit |
|---|---|---|
| Stiffener spacing | mm |
Result unit mm
Confirm in the rule set in force (DNV Pt.3 Ch.3). For primary members use shear-lag effective breadth.
| Symbol | Description | Unit |
|---|---|---|
| Sum of half-spacings to adjacent girders | m | |
| Girder span between supports | m |
Result unit m
Indicative; use the Schade-type curves in the class rules (DNV Pt.3 Ch.3) for approval work.
Result unit mm² (rules: cm²)
| Element | [mm] | [mm] | [mm²] | [mm] | [mm³] | [mm⁴] | [mm⁴] |
|---|---|---|---|---|---|---|---|
| Attached plate (b = s) | s | t_p | s·t_p | t_p/2 | … | … | s·t_p³/12 |
| Web | t_w | h_w | t_w·h_w | t_p + h_w/2 | … | … | t_w·h_w³/12 |
| Face plate (flange) | b_f | t_f | b_f·t_f | t_p + h_w + t_f/2 | … | … | b_f·t_f³/12 |
| Σ | ΣA | ΣAz | ΣAz² | ΣI_own | |||
| Results | z̄ = ΣAz/ΣA | I_NA = ΣI_own + ΣAz² − z̄²·ΣA | W_fl = I_NA/(h − z̄) | W_pl = I_NA/z̄ |
Worked example
Problem
Deck plating 10 mm, stiffener spacing 600 mm. Built-up T-stiffener: web 200 × 10 mm, face plate 80 × 12 mm. Compute the neutral axis, , the section moduli to the flange and to the plate, and the shear area. Compare with the profile alone.
Solution
Reference line: outer face of the plate. Attached plate breadth = s = 600 mm.
| Element | b | h | A [mm²] | z [mm] | A z [mm³] | A z² [mm⁴] | I_own [mm⁴] |
|---|---|---|---|---|---|---|---|
| Plate | 600 | 10 | 6000 | 5 | 30 000 | 150 000 | 50 000 |
| Web | 10 | 200 | 2000 | 110 | 220 000 | 24 200 000 | 6 666 667 |
| Flange | 80 | 12 | 960 | 216 | 207 360 | 44 789 760 | 11 520 |
| Σ | 8960 | 457 360 | 69 139 760 | 6 728 187 |
Total depth mm.
Shear area cm².
Profile alone (web + flange, Section 2.4 table): cm⁴, neutral axis 134.4 mm above the web foot, to the flange tip cm³. The attached plate raises the flange modulus by 70 % (307 vs 180 cm³) and the inertia by a factor 3.8 — which is why the stiffener must never be checked alone. The neutral axis sits at 51 mm, i.e. 23 % of the stiffener height above the plate, within the quick-estimate range.
Confirm section numbering in the edition in force.