Chapter 2 / Section 2.5
Section properties of built-up sections (stiffener + plate)
Why the plate belongs to the stiffener
A stiffener welded to plating bends together with a strip of the plate. The design section is therefore stiffener + attached plate flange; the stiffener alone has a much smaller modulus and would give a grossly conservative (wrong) stress. The neutral axis of the combined section lies close to the plate, so the flange of the stiffener is the highly stressed fibre and the plate fibre is lightly stressed.
Effective breadth of the attached plate
- Stiffeners (secondary members): classification rules take the attached plate breadth equal to the stiffener spacing for the section modulus check (DNV Rules Pt.3 Ch.3 — effective flange of secondary stiffeners; confirm the clause in the edition in force). Some rules limit it to a multiple of the plate thickness for very wide spacings.
- Girders and web frames (primary members): shear lag reduces the effective flange. The effective breadth depends on the ratio of the girder span to the flange width and on the load type; classification rules give curves (Schade curves); a common first estimate is for a girder under distributed load, where is the span and the sum of half-spacings to the neighbouring girders. Hughes & Paik Ch. 9 gives the theory.
- Buckling: when the plate is in compression (e.g. deck plating under hogging), the effective width for stiffness is further reduced to the post-buckling effective width (Section 2.10 and DNV-RP-C201).
Calculation procedure (tabular)
- Reference axis: the outer face of the plate (or the plate mid-plane). Tabulate for each part : , (centroid height), , , .
- Neutral axis height .
- .
- Section moduli: and . The flange value governs.
- Shear area: (web only).
- Report in cm³ and cm⁴ for comparison with rule requirements.
Rolled profiles
For a bulb flat (HP) or angle, take , own and centroid height from the manufacturer's table and treat the profile as one "part" in the table above. Angles and bulb flats are unsymmetrical; the rule modulus is nevertheless taken about the axis parallel to the plate because the plate prevents lateral deflection; lateral-torsional (tripping) behaviour is checked separately (Section 2.10).
Corrosion addition
Rule section moduli are compared on the net section (gross scantlings minus the corrosion addition on every plate element) in current DNV rules; older rules compared gross scantlings against a requirement that included the allowance. Always state which basis is used (Section 3.8).
Quick estimate
For a T- or angle-stiffener with attached plate, the combined modulus to the flange is roughly 1.6–2.5 times the modulus of the profile alone, and the neutral axis lies at 15–30 % of the stiffener height above the plate. Use only for sanity checks.
Formulas
| Symbol | Description | Unit |
|---|---|---|
| Area of element i (plate flange, web, face plate) | mm² | |
| Height of the centroid of element i above the reference line | mm |
Result unit mm
| Symbol | Description | Unit |
|---|---|---|
| Width and height (in the bending direction) of rectangular element i | mm |
Result unit mm⁴
Divide by 10⁴ for cm⁴.
| Symbol | Description | Unit |
|---|---|---|
| Total depth from the reference line to the top of the face plate | mm |
Result unit mm³
The smaller (flange) value governs the stress check. Divide by 10³ for cm³.
| Symbol | Description | Unit |
|---|---|---|
| Stiffener spacing | mm |
Result unit mm
Confirm in the rule set in force (DNV Pt.3 Ch.3). For primary members use shear-lag effective breadth.
| Symbol | Description | Unit |
|---|---|---|
| Sum of half-spacings to adjacent girders | m | |
| Girder span between supports | m |
Result unit m
Indicative; use the Schade-type curves in the class rules (DNV Pt.3 Ch.3) for approval work.
Result unit mm² (rules: cm²)
Tables
Tabular calculation template for a built-up section (reference line = outer face of plate)
| Element | [mm] | [mm] | [mm²] | [mm] | [mm³] | [mm⁴] | [mm⁴] |
|---|---|---|---|---|---|---|---|
| Attached plate (b = s) | s | t_p | s·t_p | t_p/2 | … | … | s·t_p³/12 |
| Web | t_w | h_w | t_w·h_w | t_p + h_w/2 | … | … | t_w·h_w³/12 |
| Face plate (flange) | b_f | t_f | b_f·t_f | t_p + h_w + t_f/2 | … | … | b_f·t_f³/12 |
| Σ | ΣA | ΣAz | ΣAz² | ΣI_own | |||
| Results | z̄ = ΣAz/ΣA | I_NA = ΣI_own + ΣAz² − z̄²·ΣA | W_fl = I_NA/(h − z̄) | W_pl = I_NA/z̄ |
Examples
Section modulus of the deck T-stiffener with attached plate
Worked example
Problem
Deck plating 10 mm, stiffener spacing 600 mm. Built-up T-stiffener: web 200 × 10 mm, face plate 80 × 12 mm. Compute the neutral axis, , the section moduli to the flange and to the plate, and the shear area. Compare with the profile alone.
References
Confirm section numbering in the edition in force.
Version 2 · last updated 19 Nov 2026 · Editor