Back to section

NavArch Handbook

Chapter 4 / Section 4.11

Effect of water density: FWA and dock water allowance

A ship of constant mass displaces a constant mass of water; when it moves into water of lower density it must displace a greater volume and therefore sinks deeper.

Fresh water allowance, FWA

The increase of draught when passing from seawater (1.025 t/m³) to fresh water (1.000 t/m³) at constant displacement:

FWA [mm]=Δ4 TPCFWA\,[\text{mm}] = \frac{\Delta}{4\,TPC}FWA[mm]=4TPCΔ​

with Δ\DeltaΔ in tonnes and TPCTPCTPC the seawater value in t/cm. The FWA is marked on the load line (the F mark above S) and is tabulated in the stability booklet for the summer displacement.

Derivation: equal mass, so 1.025 ∇SW=1.000 ∇FW1.025\,\nabla_{SW} = 1.000\,\nabla_{FW}1.025∇SW​=1.000∇FW​; the extra volume ∇FW−∇SW=∇SW(1.025/1.000−1)=0.025 ∇SW\nabla_{FW} - \nabla_{SW} = \nabla_{SW}(1.025/1.000 - 1) = 0.025\,\nabla_{SW}∇FW​−∇SW​=∇SW​(1.025/1.000−1)=0.025∇SW​ is a layer of area AWPA_{WP}AWP​; its thickness in mm is 0.025 ∇SW/AWP×10000.025\,\nabla_{SW}/A_{WP} \times 10000.025∇SW​/AWP​×1000; substituting Δ=1.025∇SW\Delta = 1.025\nabla_{SW}Δ=1.025∇SW​ and TPC=1.025AWP/100TPC = 1.025 A_{WP}/100TPC=1.025AWP​/100 gives Δ/(4 TPC)\Delta/(4\,TPC)Δ/(4TPC) (exactly Δ/(4.1 TPC)\Delta/(4.1\,TPC)Δ/(4.1TPC); the 4 is the Load Line Convention's rounding).

Dock water allowance, DWA

For water of intermediate density ρDW\rho_{DW}ρDW​ (t/m³):

DWA [mm]=FWA 1025−ρDW×100025DWA\,[\text{mm}] = FWA\,\frac{1025 - \rho_{DW}\times 1000}{25}DWA[mm]=FWA251025−ρDW​×1000​

A ship may be loaded in dock water so that her summer mark is submerged by the DWA; on reaching seawater she will rise to the mark.

General change of draught for a density change (constant displacement)

δT=Δ (ρ1−ρ2)ρ1 ρ2 AWP[m]\delta T = \frac{\Delta\,(\rho_1 - \rho_2)}{\rho_1\,\rho_2\,A_{WP}} \quad [\text{m}]δT=ρ1​ρ2​AWP​Δ(ρ1​−ρ2​)​[m]

Effect on hydrostatic data

Hydrostatic tables are normally for seawater. In fresh water, at the same draught, displacement, TPC and MCT1cm scale by 1.000/1.0251.000/1.0251.000/1.025; KBKBKB, KMKMKM, LCBLCBLCB, LCFLCFLCF (geometric quantities at that draught) do not change.

Formulas

01Fresh water allowance
FWA=Δ4 TPCFWA = \frac{\Delta}{4\, TPC}FWA=4TPCΔ​
SymbolDescriptionUnit
FWAFWAFWAFresh water allowancemm
Δ\DeltaΔDisplacement (seawater)t
TPCTPCTPCTPC in seawatert/cm

Result unit mm

02Dock water allowance
DWA=FWA 1025−1000 ρDW25DWA = FWA\,\frac{1025 - 1000\,\rho_{DW}}{25}DWA=FWA251025−1000ρDW​​
SymbolDescriptionUnit
DWADWADWADock water allowancemm
ρDW\rho_{DW}ρDW​Dock water densityt/m^3

Result unit mm

03Change of draught for a general density change
δT=Δ (ρ1−ρ2)ρ1 ρ2 AWP\delta T = \frac{\Delta\,(\rho_1 - \rho_2)}{\rho_1\,\rho_2\,A_{WP}}δT=ρ1​ρ2​AWP​Δ(ρ1​−ρ2​)​
SymbolDescriptionUnit
ρ1\rho_1ρ1​Initial water densityt/m^3
ρ2\rho_2ρ2​New water densityt/m^3
AWPA_{WP}AWP​Waterplane aream^2

Result unit m

Positive δT = increase of draught when ρ2 < ρ1.

Examples

#01

FWA and DWA for the example vessel

Worked example

Problem

Δ=6314\Delta = 6314Δ=6314 t, TPC=12.05TPC = 12.05TPC=12.05 t/cm. Find the FWA and the dock water allowance for dock water of density 1.010 t/m³.

Solution

FWA=63144×12.05=631448.2=131 mmFWA = \frac{6314}{4 \times 12.05} = \frac{6314}{48.2} = 131\ \text{mm}FWA=4×12.056314​=48.26314​=131 mm DWA=131×1025−101025=131×0.6=79 mmDWA = 131 \times \frac{1025 - 1010}{25} = 131 \times 0.6 = 79\ \text{mm}DWA=131×251025−1010​=131×0.6=79 mm

The ship may be loaded in that dock 79 mm deeper than her summer mark; on reaching seawater she rises to the mark.

References

International Convention on Load Lines, 1966/1988Clause Annex I, Reg. 6 (Load lines — fresh water mark) and Reg. 40Mandatory
Barrass & Derrett (2012)Clause Ch. 12 (Fresh water allowance and dock water allowance)Textbook