NavArch Handbook
Chapter 4 / Section 4.8
Mass that changes the mean draught by 1 cm at a given waterline. Because the added layer is 0.01 m thick, with in m² and in t/m³. In fresh water multiply the seawater TPC by .
Trimming moment (t·m) required to change the trim by 1 cm. Derived from longitudinal stability: a moment produces an angle of trim with and trim ; setting m gives . Because (the difference is negligible compared with ), the hydrostatic curves give , which depends only on geometry.
Plotted against mean draught (level keel, sometimes also for several trims):
Valid while is nearly constant (small ; use the mean TPC between the two waterlines for larger changes).
| Symbol | Description | Unit |
|---|---|---|
| Tonnes per centimetre immersion | t/cm | |
| Water density | t/m^3 | |
| Waterplane area | m^2 |
Result unit t/cm
| Symbol | Description | Unit |
|---|---|---|
| Moment to change trim 1 cm | t·m/cm | |
| Displacement | t | |
| Longitudinal metacentric height | m | |
| Length between perpendiculars (the length over which trim is measured) | m |
Result unit t·m/cm
| Symbol | Description | Unit |
|---|---|---|
| Change of mean draught (bodily sinkage) | cm | |
| Added (or removed, negative) mass | t |
Result unit cm
| Symbol | Description | Unit |
|---|---|---|
| Breadth | m |
Result unit t·m/cm
Empirical rule of thumb (Barrass & Derrett); accuracy about ±10 %. For checking only.
| [m] | [t] | [m] | [m] | [m fwd ⊗] | [m fwd ⊗] | [t/cm] | [t·m/cm] |
|---|---|---|---|---|---|---|---|
| 4.50 | 5080 | 2.33 | 6.21 | +0.95 | +1.10 | 11.60 | 54.0 |
| 5.00 | 5690 | 2.58 | 6.08 | +0.80 | +1.00 | 11.85 | 57.0 |
| 5.50 | 6314 | 2.84 | 5.98 | +0.60 | +0.88 | 12.05 | 59.8 |
| 6.00 | 6950 | 3.10 | 5.92 | +0.40 | +0.70 | 12.25 | 62.5 |
Observe the typical trends: KM_T decreases with draught while KB increases; LCB and LCF move aft as the fuller aft waterlines immerse.
Worked example
Problem
t, m, m. Find and check with the rule of thumb using t/cm and m.
Part B is recommendatory unless made mandatory by the Administration; the Administration usually requires the hydrostatic table in the approved stability booklet.