Chapter 4 / Section 4.8
TPC, MCT1cm and hydrostatic curves
Tonnes per centimetre immersion, TPC
Mass that changes the mean draught by 1 cm at a given waterline. Because the added layer is 0.01 m thick, with in m² and in t/m³. In fresh water multiply the seawater TPC by .
Moment to change trim by one centimetre, MCT1cm (also MTC)
Trimming moment (t·m) required to change the trim by 1 cm. Derived from longitudinal stability: a moment produces an angle of trim with and trim ; setting m gives . Because (the difference is negligible compared with ), the hydrostatic curves give , which depends only on geometry.
The hydrostatic curves (hydrostatic table)
Plotted against mean draught (level keel, sometimes also for several trims):
- Displacement (seawater, and sometimes fresh water)
- , (and ), (or )
- and from midship or AP
- , ,
- , , ,
- Wetted surface Modern practice gives them as a table at draught intervals (e.g. 0.1 m) in the stability booklet, computed by the hydrostatics software. The engineer must still be able to check an entry by hand.
Change of mean draught for a small added mass
Valid while is nearly constant (small ; use the mean TPC between the two waterlines for larger changes).
Formulas
| Symbol | Description | Unit |
|---|---|---|
| Tonnes per centimetre immersion | t/cm | |
| Water density | t/m^3 | |
| Waterplane area | m^2 |
Result unit t/cm
| Symbol | Description | Unit |
|---|---|---|
| Moment to change trim 1 cm | t·m/cm | |
| Displacement | t | |
| Longitudinal metacentric height | m | |
| Length between perpendiculars (the length over which trim is measured) | m |
Result unit t·m/cm
| Symbol | Description | Unit |
|---|---|---|
| Change of mean draught (bodily sinkage) | cm | |
| Added (or removed, negative) mass | t |
Result unit cm
| Symbol | Description | Unit |
|---|---|---|
| Breadth | m |
Result unit t·m/cm
Empirical rule of thumb (Barrass & Derrett); accuracy about ±10 %. For checking only.
Tables
Hydrostatic table excerpt for the 100 m example vessel (level keel, seawater) — illustrative
| [m] | [t] | [m] | [m] | [m fwd ⊗] | [m fwd ⊗] | [t/cm] | [t·m/cm] |
|---|---|---|---|---|---|---|---|
| 4.50 | 5080 | 2.33 | 6.21 | +0.95 | +1.10 | 11.60 | 54.0 |
| 5.00 | 5690 | 2.58 | 6.08 | +0.80 | +1.00 | 11.85 | 57.0 |
| 5.50 | 6314 | 2.84 | 5.98 | +0.60 | +0.88 | 12.05 | 59.8 |
| 6.00 | 6950 | 3.10 | 5.92 | +0.40 | +0.70 | 12.25 | 62.5 |
Observe the typical trends: KM_T decreases with draught while KB increases; LCB and LCF move aft as the fuller aft waterlines immerse.
Examples
MCT1cm for the example vessel
Worked example
Problem
t, m, m. Find and check with the rule of thumb using t/cm and m.
References
Part B is recommendatory unless made mandatory by the Administration; the Administration usually requires the hydrostatic table in the approved stability booklet.
Version 2 · last updated 19 Nov 2026 · Editor