Working tools · client-side
Engineering tools
Conversions, first-pass calculations and reference data that follow the relations of the handbook. Every calculation runs in the browser; nothing is sent anywhere.
Water density values used in hydrostatics
| Water | Density ρ [t/m³] | Specific volume [m³/t] | Note |
|---|---|---|---|
| Standard seawater (ICLL) | 1.025 | 0.9756 | Used for load line and class hydrostatics |
| Fresh water | 1.000 | 1.000 | Rivers, lakes, FW tanks |
| Baltic Sea (brackish, typical) | 1.005–1.012 | 0.988–0.995 | Varies with location and season |
| Dock water (typical estuary) | 1.010–1.020 | 0.980–0.990 | Measure with hydrometer before draught survey |
| Dead Sea | 1.24 | 0.806 | Extreme example |
Typical ranges of form coefficients by ship type (design waterline)
| Ship type | C_B | C_P | C_M | C_WP | Fn (typical) |
|---|---|---|---|---|---|
| Crude oil tanker / bulk carrier | 0.80–0.86 | 0.81–0.87 | 0.98–0.995 | 0.87–0.92 | 0.14–0.17 |
| General cargo ship | 0.65–0.75 | 0.68–0.77 | 0.96–0.985 | 0.78–0.85 | 0.18–0.24 |
| Container ship (Panamax) | 0.58–0.68 | 0.60–0.70 | 0.97–0.985 | 0.75–0.82 | 0.22–0.28 |
| Offshore supply vessel / PSV | 0.68–0.78 | 0.72–0.80 | 0.93–0.98 | 0.82–0.90 | 0.20–0.30 |
| Stern trawler / fishing vessel | 0.50–0.62 | 0.58–0.68 | 0.80–0.92 | 0.75–0.85 | 0.28–0.38 |
| Tug | 0.50–0.60 | 0.60–0.70 | 0.80–0.90 | 0.78–0.86 | 0.30–0.40 |
| Frigate / fast displacement craft | 0.45–0.55 | 0.58–0.65 | 0.75–0.82 | 0.70–0.78 | 0.35–0.45 |
| Ro-ro / car ferry | 0.55–0.65 | 0.60–0.70 | 0.90–0.97 | 0.78–0.86 | 0.25–0.32 |
IMO 2008 IS Code — general intact stability criteria (Part A, Ch. 2.2)
| No. | Criterion | Limit | IS Code reference |
|---|---|---|---|
| 1 | Area under GZ curve, 0° to 30° | ≥ 0.055 m·rad | Part A 2.2.1 |
| 2 | Area under GZ curve, 0° to 40° or φf | ≥ 0.090 m·rad | Part A 2.2.1 |
| 3 | Area under GZ curve, 30° to 40° or φf | ≥ 0.030 m·rad | Part A 2.2.1 |
| 4 | Righting lever GZ at heel ≥ 30° | ≥ 0.20 m | Part A 2.2.2 |
| 5 | Angle of maximum GZ | ≥ 25° (preferably > 30°) | Part A 2.2.3 |
| 6 | Initial GM0, free-surface corrected | ≥ 0.15 m | Part A 2.2.4 |
| 7 | Severe wind and rolling (weather criterion) | Area b ≥ area a; steady heel ≤ 16° or 80 % deck-edge immersion | Part A 2.3 |
Permeability values (SOLAS Ch. II-1, Reg. 7-3)
| Space | Permeability μ |
|---|---|
| Appropriated to stores | 0.60 |
| Occupied by accommodation | 0.95 |
| Occupied by machinery | 0.85 |
| Void spaces | 0.95 |
| Intended for liquids | 0 or 0.95, whichever gives the more severe requirement |
| Dry cargo spaces (at ds / dp / dl) | 0.70 / 0.80 / 0.95 |
| Container spaces (at ds / dp / dl) | 0.70 / 0.80 / 0.95 |
| Ro-ro spaces (at ds / dp / dl) | 0.90 / 0.90 / 0.95 |
| Cargo liquids (at ds / dp / dl) | 0.70 / 0.80 / 0.95 |
Steel grades — yield, tensile and material factor
| Grade | Yield ReH [MPa] | Tensile Rm [MPa] | Material factor k |
|---|---|---|---|
| A / B / D / E | 235 | 400–520 | 1.00 |
| AH32 / DH32 / EH32 | 315 | 440–570 | 0.78 |
| AH36 / DH36 / EH36 | 355 | 490–630 | 0.72 |
| AH40 / DH40 / EH40 | 390 | 510–660 | 0.68 |
Densities of common materials
| Material | Density [t/m³] |
|---|---|
| Steel | 7.85 |
| Aluminium 5083 | 2.66 |
| GRP (E-glass/polyester, ~35 % fibre by volume) | 1.6–1.9 |
| PVC foam core | 0.06–0.25 |
| Plywood | 0.55–0.70 |
| Teak | 0.65 |
| Lead | 11.34 |
| Concrete | 2.3–2.4 |
| Seawater | 1.025 |
| Marine gas oil (MGO) | 0.85 |
| Heavy fuel oil (HFO) | 0.97 |