Chapter 4 / Section 4.10
Bonjean curves and their use
Definition
A Bonjean curve is the plot, for one station, of the immersed cross-sectional area against height above the baseline. Drawn for every station on the profile of the ship, the set of curves lets the engineer read the sectional area at any waterline — level, trimmed, or a wave profile — simply by intersecting the waterline with each curve.
Construction
For each station, the area up to each waterline is obtained by Simpson integration of the half-breadths over height (Section 4.6), doubled. Often the vertical moment of area about the baseline is drawn as a second curve on the same axes.
Uses
- Displacement and LCB at a trimmed waterline — draw the trimmed waterline on the profile, read at each station, integrate longitudinally with Simpson's rule: , .
- Launching calculations — buoyancy and its centroid at successive positions of the hull on the ways.
- Longitudinal strength — buoyancy distribution on a static wave (hogging/sagging) for the still-water and wave bending moment.
- Damage stability and flooding — volume and centroid of a flooded compartment between two stations up to any waterline.
- Grounding and docking — buoyancy lost as the waterline changes.
Practical notes
- Use enough waterlines near the baseline and near the deck where the section shape changes fast.
- With modern software the Bonjean curves are implicit in the hull model; nevertheless the stability booklet for some flag states still includes them, and a hand check of one trimmed displacement from Bonjean areas is a standard verification step.
Formulas
| Symbol | Description | Unit |
|---|---|---|
| Immersed area of the station up to height z | m^2 | |
| Half-breadth of the station at height ζ | m |
Result unit m^2
| Symbol | Description | Unit |
|---|---|---|
| Height of the waterline at station x (linear for trim; sinusoidal/trochoidal for a wave) | m |
Result unit m^3
Examples
Trimmed displacement from Bonjean areas
Worked example
Problem
A 60 m vessel (stations every 6 m, 0 = AP to 10 = FP) floats at m and m. Bonjean areas read at the trimmed waterline are [m²]: 2.1, 14.8, 26.5, 34.9, 39.6, 40.8, 39.2, 33.5, 23.0, 10.4, 1.2. Find the displacement volume and LCB from midship.
References
Version 2 · last updated 19 Nov 2026 · Editor